...
시작 양식 200KG

블로그

>>

알루미늄 압출물의 내화 등급?
Updated: 12월 21, 2025
6분 읽기

알루미늄 압출물의 내화 등급?

맞춤형 LED 알루미늄 프로파일 LED 알루미늄 압출
맞춤형 LED 알루미늄 프로파일 LED 알루미늄 압출

Fire safety often becomes a problem only after a project is already designed. Aluminum profiles are light and strong, but many buyers worry about fire risk. This concern can slow decisions and raise doubts.

Aluminum extrusion itself does not burn, but its fire resistance rating depends on alloy, design, surface treatment, and system use. Aluminum melts at high temperature, so it must be evaluated as part of a complete fire-rated system.

Many buyers stop reading once they hear “aluminum melts.” That is a mistake. Fire performance is more complex, and understanding it can help make better design and sourcing choices.

What fire resistance ratings exist for aluminum structures?

Fire ratings are often confusing for aluminum buyers. Many people expect a simple number, but aluminum structures are not rated the same way as concrete or steel.

Aluminum structures usually do not have an intrinsic fire resistance rating. The rating applies to the full assembly, not the aluminum extrusion alone.

맞춤형 알루미늄 압출 CNC 가공 알루미늄 프로파일
맞춤형 알루미늄 압출 CNC 가공 알루미늄 프로파일

Aluminum behavior in fire

Aluminum is a non-combustible metal. It does not ignite or release toxic smoke. This is a strong advantage in fire scenarios. However, aluminum loses strength as temperature rises.

  • Melting point is about 660C
  • Strength drops sharply above 200C
  • Shape stability depends on profile design

This means aluminum is safe from a burning point of view, but not from a load-bearing point of view in fire.

Fire resistance ratings explained

Fire resistance ratings are measured in time. Common values include 30, 60, 90, and 120 minutes. These numbers describe how long a structure can meet certain criteria during a standard fire test.

The test checks three main things:

  1. 하중 지지 용량
  2. Integrity against flame passage
  3. Insulation against heat transfer

Aluminum extrusions alone usually fail load-bearing criteria early. But when used inside systems, the result can change.

Typical aluminum applications and ratings

Application area Fire rating approach Typical rating
Curtain wall frames System tested with glass and seals 30 to 60 min
창틀 Often non-rated or limited rating 0 to 30 min
산업 프로필 Depends on enclosure System based
Solar mounting rails Usually non-rated Not required

In many projects, aluminum is allowed because it is not the main load-bearing element during fire.

Design strategies to improve fire performance

Design has a big effect on fire results. Thick walls, closed sections, and thermal breaks can delay heat transfer.

일반적인 방법에는 다음이 포함됩니다:

  • Increasing wall thickness
  • Adding fire-resistant boards
  • Using intumescent coatings
  • Designing aluminum as secondary structure

These methods do not change the aluminum itself. They change how the system reacts in fire.

Aluminum extrusions are non-combustible and do not contribute fuel to a fire.True

Aluminum does not burn or ignite under normal fire conditions and is classified as non-combustible.


Aluminum profiles always have a 60-minute fire resistance rating by default.False

Fire ratings apply to tested assemblies, not to aluminum extrusions by themselves.

How does surface treatment affect fire performance?

Surface treatment is often chosen for looks or corrosion resistance. Fire behavior is rarely discussed, but it matters in some cases.

Surface treatment does not change aluminum melting point, but it can affect smoke, flame spread, and surface reaction.

알루미늄 압출 밀링 절단 및 조립
알루미늄 압출 밀링 절단 및 조립

Common aluminum surface treatments

The most common treatments include:

  • 아노다이징
  • 파우더 코팅
  • PVDF 코팅
  • 전기 영동
  • Mechanical finishing

Each treatment adds a thin layer to the aluminum surface.

Fire behavior of coatings

Coatings are organic or inorganic. This difference is critical in fire.

Organic coatings, like powder coating and PVDF, can:

  • Burn or decompose
  • Produce smoke
  • Affect flame spread classification

Inorganic coatings, like anodizing, do not burn.

Flame spread and smoke development

Many fire codes focus on two indexes:

  • Flame spread index
  • Smoke development index

Surface coatings can raise both values.

표면 처리 Combustibility Smoke risk Fire impact
아노다이징 불연성 매우 낮음 최소
파우더 코팅 Combustible Medium 보통
PVDF 코팅 Combustible 중간에서 높음 더 높음
전기 영동 낮음 낮음 제한적

This is why some public projects restrict coated aluminum in escape routes.

Heat transfer and coating thickness

Coatings are thin. Typical thickness is:

  • Anodizing: 10 to 25 microns
  • Powder coating: 60 to 120 microns

These layers do not provide insulation. Heat passes through quickly. Fire resistance time does not increase.

Choosing surface treatment for fire-sensitive projects

For projects like:

  • Metro stations
  • 공항
  • 병원
  • High-rise stairwells

Anodized aluminum is often preferred. It meets non-combustible requirements more easily.

Anodizing does not add combustible material to aluminum surfaces.True

Anodizing creates an oxide layer that is inorganic and non-combustible.


Powder coating improves aluminum fire resistance time.False

Powder coating does not increase fire resistance time and may add combustible material.

Can anodized aluminum resist high temperatures?

Anodized aluminum is often seen as more fire safe. This is partly true, but it needs clear explanation.

Anodized aluminum resists surface damage at high temperature, but it still loses strength as the base aluminum heats up.

공장 가격 맞춤형 알루미늄 압출 방열판
공장 가격 맞춤형 알루미늄 압출 방열판

What anodizing really does

Anodizing converts the aluminum surface into aluminum oxide. This layer is:

  • 하드
  • 안정적
  • 불연성

Aluminum oxide has a much higher melting point than aluminum metal.

Temperature resistance comparison

Material layer Approximate stability
Aluminum metal Loses strength above 200C
Anodized oxide layer Stable above 1000C
파우더 코팅 Degrades around 200-300C

This means the surface remains intact longer, but the structure underneath still weakens.

Visual appearance in fire exposure

Anodized aluminum often:

  • Changes color
  • Shows surface dulling
  • Keeps coating integrity

Powder-coated aluminum often:

  • Bubbles
  • Peels
  • Produces smoke

This difference matters for post-fire inspection and safety evaluation.

Structural limits remain

Even with anodizing:

  • Load capacity drops fast
  • Deflection increases
  • Connections may fail

Anodizing is not a fireproof solution. It is a safer surface option.

Practical use cases

Anodized aluminum is commonly used in:

  • Fire escape handrails
  • Facade sub-frames
  • Interior public spaces
  • 교통 허브

It meets non-combustible surface rules but still relies on system design for fire rating.

Anodized aluminum maintains surface stability at very high temperatures.True

The anodized oxide layer is stable at temperatures much higher than aluminum metal.


Anodizing allows aluminum to keep full structural strength in fire.False

Anodizing does not prevent aluminum from losing strength as temperature rises.

Which regulations define fire rating requirements?

Fire rating rules depend on region and building type. Aluminum buyers must understand which standards apply before quoting or designing.

Fire rating requirements come from building codes and test standards, not from aluminum material specifications alone.

LED 조명 시스템용 알루미늄 압출
LED 조명 시스템용 알루미늄 압출

Main international fire standards

Different markets use different systems.

  • Europe: EN standards
  • United States: ASTM and NFPA
  • Middle East: Civil defense codes
  • Japan: Building Standard Law

Aluminum extrusions must fit into these frameworks.

European classification system

In Europe, reaction to fire is classified from A1 to F.

  • A1: Non-combustible
  • A2: Limited contribution
  • B to F: Increasing fire risk

Bare aluminum and anodized aluminum usually meet A1 or A2. Coated aluminum may fall into lower classes unless tested.

Fire resistance versus reaction to fire

These are different concepts.

Reaction to fire:

  • How material contributes to fire
  • Flame spread
  • Smoke

Fire resistance:

  • How long an assembly resists fire
  • Measured in minutes

Aluminum often passes reaction to fire but fails fire resistance alone.

Common regulatory expectations

Building type Typical requirement
주거용 Limited fire resistance
상업용 30 to 60 min systems
High-rise Strict system testing
산업 Case specific

This is why aluminum is widely used but rarely alone in fire-rated elements.

Buyer responsibility in compliance

Manufacturers supply profiles. Designers define systems. Contractors install assemblies.

Buyers should:

  • Ask for fire test reports
  • Confirm surface treatment class
  • Match product use to code

This avoids risk at inspection stage.

Fire resistance requirements are defined by building codes and tested assemblies.True

Codes and standards define how systems must perform in fire, not individual materials alone.


All aluminum extrusions automatically meet global fire rating rules.False

Compliance depends on application, surface treatment, and tested system design.

결론

Aluminum extrusions are safe, non-combustible, and widely accepted in construction. Fire resistance ratings depend on system design, surface treatment, and regulation. Understanding these limits helps buyers choose aluminum with confidence.

Eva

아직도 답을 찾지 못하셨나요? 아래 버튼을 클릭하여 무료 상담을 받으세요, 에바가 도와드리겠습니다.
무료 상담 받기

최근 게시물

  • 1월 14, 2026

    운송 장비용 알루미늄 압출?

    아노다이징 하우징 대형 알루미늄 압출 운송 장비는 지속적인 압력에 직면합니다. 차량은 더 가볍고, 더 안전해야 하며, 더 ...
    자세히 보기 >>
    아노다이징 하우징 대형 알루미늄 압출품
  • 1월 13, 2026

    알루미늄 압출 피로 강도 요구 사항?

    알루미늄 압출 칠판 화이트 보드 프레임 알루미늄 프로파일 피로 고장은 종종 경고없이 나타납니다. 많은 구매자가 ...
    자세히 보기 >>
    알루미늄 압출 칠판 화이트보드 프레임 알루미늄 프로파일
  • 1월 12, 2026

    알루미늄 압출 진동 저항 수준?

    알루미늄 압출 초소형 소재 알루미늄 프레임 프로파일 진동은 소음, 피로 및 고장을 유발합니다. 많은 구매자가...
    자세히 보기 >>
    알루미늄 압출 초소형 소재 알루미늄 프레임 프로파일

메시지 보내기

Google 재캡차: 잘못된 사이트 키입니다.